X-ray System GR10X-40K
- height-adjustable chest bucky with smooth tracks for detector change
- LED light at the top of bucky stand as status indicator
- LCD display monitor
- wheel controller on console for easy use
- rotatable stand console handle for better mobility
- slidable table with curved edges for better safety and mobility
Superior Image Quality
Model Name | GR10X-40K |
---|---|
Generator Power Input | 230VAC ± 10 %, 50/60 Hz 400 - 480 VAC, 50/60 Hz |
Generator Power Output | 40kW, 1 phase & 3 phrase |
Generator kV Range | 40-150 kV |
Generator mA range | 10-500 mA |
Generator mAs range | 0.1 - 630 mAs |
CE Mark | CE0197 |
Tube kV Range | 40 -125 kV |
Tube Rotation | Rotating 16° at high speed |
Tube Anode Heat Storage Capacity | 100 kJ (140 kHU) |
Tube Focus | Small focus: 1.0 mm Large focus: 2.0 mm |
Collimator Power Input | 24VAC, 50/60 Hz |
Collimator Max Tube Voltage | 150 kV |
Collimator Light Source | LED lamp 24 VAC 1A/24VDC 1A |
Collimator Inherent Filtration | Inherent filtration 1.2 mmAl |
Collimator Field Size | Max field size : less than 48 cm x 48 cm at SID 100 cm |
Tube Stand Power Input | 220VAC, 50/60 Hz |
Tube Stand Column Rotation | ± 180° with electro-mechanical detent at each 90° |
Tube Stand Horizontal Rotation of X-ray beam | Horizontal Rotation of X-ray beam |
Tube Stand Travel Distance | Vertical : 1470 mm (413 mm to 1883 mm ) Longitudinal : Approx. 1700 mm (Rail 2210 mm ) Lateral : Approx. 183 mm |
Bucky Table Power Input | 24VDC |
Bucky Table Size (L x W x H) | Size (L x W x H) |
Bucky Table Max. load of Tabletop | 300 kg |
Bucky Table Table Movable Distance | Longitudinal : ± 300 mm, Transverse : ± 125 mm |
Bucky Table Locking System | Electromagnetic lock |
Bucky Table Inherent Filtration | 0.8 mmAl |
Bucky Stand Power Input | 24 VDC |
Bucky Stand Inherent Filtration | 0.5 mmAl |
Bucky Stand Vertical Movement | Approx. 1404 mm |
X-ray System GR10X-50K
- height-adjustable chest bucky with smooth tracks for detector change
- LED light at the top of bucky stand as status indicator
- LCD display monitor
- wheel controller on console for easy use
- rotatable stand console handle for better mobility
- slidable table with curved edges for better safety and mobility
Superior Image Quality
Model Name | GR10X-50K |
---|---|
Generator Power Input | 400 – 480 VAC, 50/60 Hz |
Generator kV Range | 40 – 150 kV |
Generator mA range | 10 – 630 mA |
Generator mAs Range | 0.1 – 630 mAs |
CE Mark | CE0197 |
Tube kV Range | 40 – 150 kV |
Tube Rotation | Rotating 12° at high speed |
Tube Anode Heat Storage Capacity | 210 kJ (300 kHU) |
Tube Focus | Small focus: 0.6 mm Large focus: 1.2 mm |
Collimator Power Input | 24VAC, 50/60 Hz |
Collimator Max Tube Voltage | 150 kV |
Collimator Light Source | LED lamp 24 VAC 1A/24VDC 1A |
Collimator Inherent Filtration | Inherent filtration 1.2 mmAl |
Collimator Field Size | Max field size : less than 48 cm x 48 cm at SID 100 cm |
Tube Stand Power Input | 220VAC, 50/60 Hz |
Tube Stand Column Rotation | ± 180° with electro-mechanical detent at each 90° |
Tube Stand Horizontal Rotation of X-ray beam | ± 180° with manual lock |
Tube Stand Travel Distance | Vertical : 1470 mm (413 mm to 1883 mm ) Longitudinal : Approx. 1700 mm (Rail 2210 mm ) Lateral : Approx. 183 mm |
Bucky Table Power Input | 24VDC |
Bucky Table Size (L x W x H) | 2000 x 750 x 657 (mm) |
Bucky Table Max. load of Tabletop | 300kg |
Bucky Table Table Movable Distance | Longitudinal : ± 300 mm Transverse : ± 125 mm |
Bucky Stand Inherent Filtration | 0.8 mmAl |
Bucky Table Locking System | Electromagnetic lock |
Bucky Stand Power Input | 24 VDC |
Bucky Stand Inherent Filtration | 0.5 mmAl |
Bucky Stand Vertical Movement | Approx. 1404 mm |